Skip to content

Floor plate methodology — key plans and tiles

The floor plate methodology is a geometric space-planning system in which every square foot of a building is assigned to a named Key Plan that traces directly to real furniture dimensions. A Key Plan is the smallest unit: a labelled rectangle around one tenant's actual furniture inventory, sized to enclose desks, storage, circulation, and accessibility clearances. A Tile is a composable group of Key Plans — each Tile is exactly one HVAC climate zone. A Floor Plate is the assembly of Tiles plus a Building Core plus Special Tiles; nothing on the floor is left unrepresented. Tile geometry follows the Building Width Calculator and the zone depths per use type; named assembly examples are catalogued in floor-plate tile combinations.

The system is defined in the V12 Methodology (May 2025) and V12 Tear Sheet (January 2026) as "a geometric self-similar aperiodic space-planning system based on furniture and equipment arrangements and circulation versus modular area-per-person progressions."

Three properties qualify the system:

  • Aperiodic — Tiles do not repeat on a fixed grid.
  • Self-similar — each Tile is exactly one HVAC climate zone, regardless of size.
  • Geometric — all dimensions resolve to real metric measurements driven by real furniture SKUs (Steelcase, Midmark, Treston, Agati).

The three tile families

Family Area Role
Small 2,700 SF 250.84 Most flexible; smallest unit of climate-zone autonomy
Medium 3,500 SF 325.16 Bridge family; absorbs short-side geometry
Large 4,900 SF 455.22 Corporate anchor; approaches 1/4 floor tile

Source: V12 Methodology p. 2. The Medium family is documented in the V12 Methodology PDF but is currently absent from tile-system.dtcg.json — flagged as a token-store gap.

Tile composition rules

These rules govern how Tiles compose into a valid Floor Plate. They are encoded as FP-* validators in the planned tool-floorplates Rust crate.

FP-SUM — every square foot is represented

The aggregate of Basic Tiles + Compound Tiles + Special Tiles + the Building Core sums to the full Net Leasable Area within a ±100 SF tolerance. No free space exists without a corresponding Key Plan.

FP-ENDCAP — short sides receive natural light

The two ends of the building use End Cap tiles:

  • Small-family End Caps: Tile B-1 (Private 2,700 SF), Tile E-1 (Mixed Left 2,700 SF), Tile E-2 (Mixed Right 2,700 SF).
  • 6,000 SF paired End Caps: Tile A-1 (Corporate), Tile B-2 (Private), Tile C-3 (Professional Medium), Tile C-4 (Professional Large).
  • Medium-family End Caps: Tile E-1 (Private Office Medium variant) and Tile E-2 (Professional Office Medium variant), each approximately 3,500–5,500 SF.

End Caps must receive natural light on both perpendicular axes; an End Cap with no window on one axis triggers a window-bay revision (V12 Methodology p. 8, Sample #3/#4).

FP-CORE — Offset Pulled Back Core

The Building Core (Elevators, Service Stairs, Emergency Stairs, Restrooms, Meter Room, Mop Room) is positioned at least 18 m from the short end of the building. This leaves enough plate length for two End Cap tiles plus at least one Basic Tile on each side of the core.

FP-SNAP — Special Tile width matches Key Plan width

Special Tiles SP-A, SP-B, SP-C fill the residual area surrounding the Core. Their width is snapped to the nearest Professional Office Key Plan width. This preserves demising-wall continuity. SP-C, in front of the Core, must avoid direct alignment of any door with the elevator opening (V12 Methodology p. 9).

FP-CLIMATE — one tile, one HVAC zone

Each Tile is an independent climate zone. Tenants who combine Tiles combine climate-control authority; the leasing agreement prices this trade-off explicitly. Smaller tiles increase tenant autonomy; larger tiles reduce zone count in favour of contiguous space.

FP-DOORS — door count per tile and per floor

Each tile may carry up to 10 doors; each floor may carry up to 80 doors. The door count is one of the cost drivers in the leasing economics — every door is also a Service Hookup (electric, data, HVAC tap).

FP-CORNER — small tiles at corners trigger structural review

When a Small-family tile lands at a structural corner, the column grid is reviewed before the tile is finalised. Small tiles may conflict with the structural module; the core position is adjusted if the short-side tiles conflict (V12 Methodology p. 2, Inventory of Tiles note).

Floor-plate dimensional range

Class Net leasable per floor Floor count
Professional Centres 19,000 – 23,000 SF 3 – 5 floors
Suburban Office 17,000 – 21,000 SF 6 – 9 floors
Retail Select 4,500 / 6,700 / 7,700 SF varies
Tech Industrial 7,200 / 8,400 SF varies

Source: V1 Combinations PDF p. 2 (formal algebra).

Why "geometric self-similar aperiodic" matters

  • Geometric — every dimension cites a furniture SKU plus a regulatory clearance, not a developer rule of thumb.
  • Self-similar — a Tile at 2,700 SF is the same kind of object as a Tile at 4,900 SF: one climate zone, one leasable instrument.
  • Aperiodic — tiles do not repeat on a fixed grid. A floor can carry a different tile sequence on every level.

Floor-plate composition example

From V12 Methodology p. 4 (Sample Small Tile):

  • Tile A (Corporate Office 2,700) ×2 left of left emergency stairs
  • Tile A (Corporate Office 2,700) ×2 between emergency stairs
  • Special Tile A (400 SF) — core-adjacent left
  • Building Core
  • Special Tile B (300 SF) — core-adjacent right
  • Tile A (Corporate Office 2,700) — right of core
  • Tile A ×2 (5,400 SF combined) at right end

Basic Tiles: 18,900 SF. Special Tiles: 1,100 SF. Total: 20,000 SF.

Open research

  • Q1. The token store lists E-1 and E-2 as 2,700 SF Small End Caps. The V12 Methodology shows them as Medium End Caps at approximately 3,500–5,500 SF. Which convention is authoritative?
  • Q2. SP-C is documented at 4,700 SF in front of the Core. How does it interact with the Elevator Lobby for compositions using Medium tiles?
  • Q3. What is the exact derivation of the 18 m minimum core-to-short-end distance? Inferred from end-cap and first-tile width, but no PDF cites the figure directly.
  • Q4. The Tile B-1 token records 1,800 SF office + 900 SF corridor. The May Methodology shows 5 PO modules summing to 1,850 SF + 850 SF residual. Which composition is current?
  • Q5. The 100 SF tolerance in FP-SUM is operator policy, not source-document text. Confirm the tolerance band before encoding.

See also

Important Information

Important Information

Securities offering. Woodfine Capital Projects Inc. ("Woodfine") sponsors real-property direct-hold solutions. Interests in those solutions are offered only to investors who qualify under an applicable prospectus exemption — including the accredited-investor exemption under National Instrument 45-106 — Prospectus Exemptions, and equivalent exemptions in other applicable jurisdictions. Content on this wiki is provided for general informational purposes only and does not constitute an offer to sell, or a solicitation of an offer to buy, any security. Any offering is made exclusively by means of the applicable Private Placement Memorandum, which prospective investors should review, together with their own professional advisors, before investing.

Scope. This wiki describes Woodfine's research methodology, geographic data platform, and related activities at a high level and is qualified in its entirety by the applicable Private Placement Memorandum and the governing documents of the relevant issuer.

Risk. Investment in real-property direct-hold solutions involves significant risk, including possible loss of capital. Past performance is not indicative of future results. References to structural features such as advisory fees, transferability, and net asset value methodology describe the contractual terms of the direct-hold solutions and are not representations as to investment outcomes or returns.

Forward-looking statements. Statements that are not historical facts may constitute forward-looking information within the meaning of applicable Canadian securities laws. Such statements are subject to known and unknown risks, uncertainties and assumptions, and actual results may differ materially. Woodfine undertakes no obligation to update such statements except as required by law.

Registration. Registrable activities of Woodfine and its affiliates are conducted, where required, under the applicable registration categories prescribed by the British Columbia Securities Commission and other Canadian securities regulators. Specific registration details are available on request.

Jurisdiction. Woodfine Capital Projects Inc. is organized in British Columbia, Canada. References to the Sovereign Data Foundation on this wiki describe a planned or intended initiative only, not a current equity holder or active governance body.

Trademarks. See TRADEMARK.md in this repository for the full trademark notice.

Changes to this notice. Woodfine may update this notice from time to time; the version posted on this page governs.

Not a filing system. This wiki is not a securities filing system, an electronic disclosure repository, or a substitute for SEDAR+ or any other regulatory filing system. Formal securities filings are made through the applicable regulatory filing system, not through this wiki.

Full disclaimer. This notice supplements, and does not replace, the full Disclaimers article. In the event of any conflict, the full Disclaimers article governs.

Read the full disclaimer →